{"id":3236,"date":"2021-02-23T15:00:00","date_gmt":"2021-02-23T06:00:00","guid":{"rendered":"https:\/\/www.naccorporation.com\/en\/learning-center\/video-contents\/3236"},"modified":"2022-10-31T13:53:33","modified_gmt":"2022-10-31T04:53:33","slug":"pc-software-wireexpress-hi-pot-for-cable-harness-testers-for-nmg-nmk-nm1500p-nm1500k","status":"publish","type":"video-contents","link":"https:\/\/www.naccorporation.com\/en\/learning-center\/video-contents\/3236","title":{"rendered":"PC Software WireExpress Hi-Pot for Cable Harness Testers (for NMG+\/NMK\/NM1500P\/NM1500K)"},"content":{"rendered":"<br \/>\r\n<br \/>\r\n<h2 class=\"c-headline02\">Text and images from this video<\/h2>\r\n\r\n\r\n<h3 class=\"c-headline03\">Setting<\/h3>\r\n<div class=\"c-spacer--s\">\r\n<p class=\"c-textBig\">Prepare Harness multi tester and PC installed the Software \"WireExpress Hi-Pot\" <\/br>\r\nTurn on the tester and connect to the PC with PC cable.<\/br>\r\nStart the software.<\/br>\r\nNon-connection is displayed.<\/br>\r\nYou need to set the com port.<\/br><\/br>\r\n\r\nInput default Manager ID ,nacman790.<\/br>\r\nPlease open the Setting.<\/br>\r\n\r\nSet COM port. If the tester is connected to PC, the COM Port will be displayed.<\/br>\r\nIf it is not displayed, the tester is not connected properly. Please check the PC cable or the Software driver install. <\/br>\r\n\r\nAfter setting the COM, Please go back to MENU.<\/br>\r\nThe tester name will be displayed in a few seconds.<\/br>\r\nThen the connection is completed.<\/br><\/br>\r\n\r\nThere are two types of login. Checker, and Manager.<\/br>\r\nThe checker can operate only parts for testing.<\/br>\r\nThe Manager can operate all functions of this software including creating test data and management of test reports.<\/br>\r\nIf you log in, the buttons will be active depending on the login type.<\/br><\/br>\r\n\r\nLet's check the Setting again.<\/br>\r\nIn setting, you can set the default test specification, test setting and ID registration.<\/p><\/br>\r\n<img src=\"https:\/\/www.naccorporation.com\/en\/wp-content\/uploads\/2020\/10\/WEH_Setting.png\" alt=\"Setting test spec for cable harness tester\" \/> \r\n\r\n<\/div>\r\n\r\n<hr class=\"c-hr\" \/>\r\n<\/hr>\r\n<div class=\"c-spacer--s\">\r\n<h3 class=\"c-headline03\">Sampling<\/h3>\r\n\r\n<p class=\"c-textBig\">Create test data easily with OK cable.<\/br>\r\nPlease connect the test target via the jig.<\/br>\r\nInput the product name and comment.<\/br>\r\nThe comment is available for jigs and instructions.<\/br>\r\n\r\nIf you are ready, press the start button.<\/br>\r\nThe circuits are displayed. Please check them with the diagram.<\/br>\r\nPlease press register to complete creating test data.<\/p><\/br>\r\n<img src=\"https:\/\/www.naccorporation.com\/en\/wp-content\/uploads\/2020\/10\/WEH_Sampling.png\" alt=\"Connecting the test cable to the test fixture for creating test data by sampling. \" \/>\r\n<\/div>\r\n<hr class=\"c-hr\" \/><\/hr>\r\n<div class=\"c-spacer--s\">\r\n<h3 class=\"c-headline03\">Test<\/h3>\r\n<p class=\"c-textBig\">This is the test screen.<\/br>\r\nIf you click start, the test will run.<\/br>\r\nTest results and measurements are displayed.<\/br>\r\nThe test was completed and passed.<\/br>\r\nThe test report is stored on the PC.<\/br><\/br>\r\n\r\nLet's check the test failed.<\/br>\r\n\r\nIt is in NG. <\/br>\r\nYou can check the NG content.<\/br><\/br>\r\n\r\nYou can change the start mode.<\/br>\r\nAuto-start is useful for consecutive tests.<\/br>\r\nIn this mode, the test starts by inserting connectors to the fixture after the first test passed.<\/p><\/br>\r\n<img src=\"https:\/\/www.naccorporation.com\/en\/wp-content\/uploads\/2020\/10\/WEH_Test.png\" alt=\"Testing cabel by WireExpress Hi-Pot \" \/>\r\n<\/div>\r\n<hr class=\"c-hr\" \/>\r\n<\/hr>\r\n<div class=\"c-spacer--s\">\r\n<h3 class=\"c-headline03\">Data Management<\/h3>\r\n<p class=\"c-textBig\">Let's check the data management.<\/br>\r\nYou can create and edit the test data here.<\/br>\r\nEdit for detail setting such as setting resistance judgment value for each circuit, High voltage applying, and so on.<\/br><\/br>\r\n\r\nPlease open the test data you created.<\/br>\r\nLet's edit this data.<\/br>\r\nIf you change the product name, this data will be saved as new test data.<\/br>\r\nYou can change the test spec here.<\/br>\r\nAdd the circuit by inputting information to the bottom cell column.<\/br>\r\n\r\nThe upper and lower resistance values can be set for each circuit.<\/br>\r\n\r\nFor creating data by manual, please click Manual Register.<\/br>\r\nYou can get blank data and input as you like.<\/p><\/br>\r\n<img src=\"https:\/\/www.naccorporation.com\/en\/wp-content\/uploads\/2020\/10\/WEH_Data.png\" alt=\"Detailed test data settings for cable harness testing by WireExpress Hi-Pot\" \/>\r\n<\/div>\r\n<hr class=\"c-hr\" \/>\r\n<\/hr>\r\n<div class=\"c-spacer--s\">\r\n<h3 class=\"c-headline03\">Search<\/h3>\r\n<p class=\"c-textBig\">Search is the function to check or test the connection by touching with the probe.<\/br>\r\nA simple search is for just checking the pin you touch with the probe.<\/br>\r\n\r\nThe memory test is for the test with search test data.<\/br>\r\nLet's create search test data.<\/br>\r\nPlease click register.<\/br>\r\n\r\nYou can select \"order search\" or \"random search\".<\/br>\r\n\r\nClick start and touch the pins.<\/br>\r\nCheck the pins. click register to save data.<\/br>\r\n\r\nLet's open the test data.<\/br>\r\nStart the test.<\/br>\r\nIf you touch all pins displayed, the test is passed.<\/br>\r\nTouch the wrong pin or can't find the connection, please click NG.<\/br>\r\n\r\nSame as test data, Search test data can be edited by manual.<\/p><\/br>\r\n<img src=\"https:\/\/www.naccorporation.com\/en\/wp-content\/uploads\/2020\/10\/WEH_Search.png\" alt=\"Testing a cable harness by touching with the probe by WireExpress Hi-Pot\" \/>\r\n<\/div>\r\n<hr class=\"c-hr\" \/><\/hr>\r\n<div class=\"c-spacer--s\">\r\n<h3 class=\"c-headline03\">Step Test<\/h3>\r\n<p class=\"c-textBig\">\r\nStep test is a useful function for testing circuit-changing cables by the switch.<\/br>\r\nThis is the test to conduct more than two tests in a row.<\/br>\r\n\r\nLet's create STEP test data.<\/br>\r\nPlease select test data from the data you created.<\/br>\r\n \r\nOpen the step test data.<\/br>\r\nYou can run as a normal test.<\/br>\r\nThe second test is ready after the first test passed.<\/p><\/br>\r\n<img src=\"https:\/\/www.naccorporation.com\/en\/wp-content\/uploads\/2020\/10\/WEH_Step.png\" alt=\"Step test is ideal for cable harness testing including switches.\" \/>\r\n<\/div>\r\n<hr class=\"c-hr\" \/>\r\n<\/hr>\r\n<div class=\"c-spacer--s\">\r\n<h3 class=\"c-headline03\">Test Report<\/h3>\r\n<p class=\"c-textBig\">All test reports are saved by each test.<\/br>\r\nLet's check them in this part.<\/br>\r\nPlease decide the condition and click enter.<\/br>\r\n \r\nSelect the test report and click DETAIL.<\/br>\r\nSelect the line and click the test data. The test report will be written out.<\/br>\r\n \r\nOpen the test report.<\/br>\r\nIt contains information about the date and time, the test spec, the measured value, and the result.<\/p><\/br>\r\n<img src=\"https:\/\/www.naccorporation.com\/en\/wp-content\/uploads\/2020\/10\/WEH_Report.png\" alt=\"Reports of the cable harness testing by WireExpress Hi-Pot\" \/>\r\n<\/div>\r\n<hr class=\"c-hr\" \/>\r\n<\/hr>\r\n<div class=\"c-spacer--s\">\r\n<h3 class=\"c-headline03\">Self-Diagnosis<\/h3>\r\n<p class=\"c-textBig\">\r\nSelf-diagnosis is the function to check the tester before testing.<\/br>\r\nFor the daily check, please conduct a scanner test.<\/br>\r\nRemove all test cables from the tester connectors before click start.<\/br>\r\n\r\nIt shows \"pass\".The tester is normal.<\/br>\r\nIf NG occurs, please check your environments.<\/br>\r\nPlease contact us in case of tester failure.<\/p><\/br>\r\n\r\n<img src=\"https:\/\/www.naccorporation.com\/en\/wp-content\/uploads\/2020\/10\/WEH_Self-Diagnosis.png\" alt=\"Self-diagnosis of the cable harness tester by WireExpress Hi-Pot\" \/>\r\n<\/div>\r\n<hr class=\"c-hr\" \/>\r\n<\/hr>\r\n\r\n\r\n<div class=\"u-taCenter\"><a class=\"c-btn c-btn--l p-pageBtnForm\" href=\"\/en\/faq\">Watch More Videos<\/a><\/div>\r\n\r\n","protected":false},"author":1,"featured_media":3237,"menu_order":61,"template":"","meta":[],"video-cat":[152],"video-tag":[134,133,140,136],"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/www.naccorporation.com\/en\/wp-json\/wp\/v2\/video-contents\/3236"}],"collection":[{"href":"https:\/\/www.naccorporation.com\/en\/wp-json\/wp\/v2\/video-contents"}],"about":[{"href":"https:\/\/www.naccorporation.com\/en\/wp-json\/wp\/v2\/types\/video-contents"}],"author":[{"embeddable":true,"href":"https:\/\/www.naccorporation.com\/en\/wp-json\/wp\/v2\/users\/1"}],"version-history":[{"count":0,"href":"https:\/\/www.naccorporation.com\/en\/wp-json\/wp\/v2\/video-contents\/3236\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.naccorporation.com\/en\/wp-json\/wp\/v2\/media\/3237"}],"wp:attachment":[{"href":"https:\/\/www.naccorporation.com\/en\/wp-json\/wp\/v2\/media?parent=3236"}],"wp:term":[{"taxonomy":"video-cat","embeddable":true,"href":"https:\/\/www.naccorporation.com\/en\/wp-json\/wp\/v2\/video-cat?post=3236"},{"taxonomy":"video-tag","embeddable":true,"href":"https:\/\/www.naccorporation.com\/en\/wp-json\/wp\/v2\/video-tag?post=3236"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}