{"id":3234,"date":"2021-02-23T15:00:00","date_gmt":"2021-02-23T06:00:00","guid":{"rendered":"https:\/\/www.naccorporation.com\/en\/learning-center\/video-contents\/3234"},"modified":"2022-10-31T14:28:42","modified_gmt":"2022-10-31T05:28:42","slug":"how-to-measure-a-cable-harness-with-hi-pot-cable-harness-testers-dielectric-withstand-testing-insulation-resistance-testing","status":"publish","type":"video-contents","link":"https:\/\/www.naccorporation.com\/en\/learning-center\/video-contents\/3234","title":{"rendered":"How to measure a Cable Harness with Hi-Pot Cable Harness Testers | Dielectric Withstand Testing \/ Insulation Resistance Testing"},"content":{"rendered":"\r\n<br \/>\r\n<br \/>\r\n<h2 class=\"c-headline02\">Text and Images for Operation of Hi-Pot Cable Harness Testers <\/h2>\r\n\r\n<div class=\"c-spacer--s\">\r\n<h3 class=\"c-headline03\">Test Spec<\/h3>\r\n<p class=\"c-textBig\">\r\nThis is a harness tester NMG+.<\/br>\r\nThe operation of NMK is the same as that of NMG+.<\/br>\r\nPlease turn on it. MENU is displayed.<\/br>\r\n\r\nLet's set the test spec.<\/br>\r\nPlease select No.3 function to set the test spec.<\/br>\r\nYou can set the test specs for creating test data.<\/br>\r\nYou can finish the settings after you select all specs with the set button.<\/br>\r\nIf you quit it in the middle with the escape button, it will not be reflected.<\/br>\r\n\r\n<div class=\"c-spacer--s\">\r\n<img src=\"https:\/\/www.naccorporation.com\/en\/wp-content\/uploads\/2020\/12\/Hi-Pot-Cable-Harness-Testers_Test-Spec.png\" alt=\"Hi-Pot Cable Harness Testers_Test Spec\" \/>\r\n<\/div>\r\n\r\n<\/p>\r\n\r\n<\/div>\r\n<hr class=\"c-hr\" \/>\r\n<\/hr>\r\n\r\n<div class=\"c-spacer--s\">\r\n<h3 class=\"c-headline03\">Test Connectors<\/h3>\r\n<p class=\"c-textBig\">NMG+ and NMK have different tester connectors.<\/br>\r\nNMK has a 32-pin connector to accommodate 1000V voltage testing.<\/p>\r\n<\/div>\r\n\r\n<div class=\"c-spacer--s\">\r\n<img src=\"https:\/\/www.naccorporation.com\/en\/wp-content\/uploads\/2020\/12\/Hi-Pot-Cable-Harness-Testers_Test-Connectors.png\" alt=\"Hi-Pot Cable Harness Testers_Test Connectors\" \/>\r\n<\/div>\r\n\r\n<div class=\"c-spacer--s\">\r\n<h3 class=\"c-headline03\">Sampling<\/h3>\r\n<p class=\"c-textBig\">\r\nLet's create test data.<\/br>\r\nThe operation is common to these models.<\/br>\r\nPlease select No.2, Sampling.<\/br>\r\nSampling is the function to read the wiring of the test target and create test data by combining it with the test spec you set.<\/br>\r\n\r\nPlease connect test target to the tester and press set button to read the wiring.<\/br>\r\n<div class=\"c-spacer--s\">\r\n<img src=\"https:\/\/www.naccorporation.com\/en\/wp-content\/uploads\/2020\/12\/Hi-Pot-Cable-Harness-Testers_Sampling.png\" alt=\"Hi-Pot Cable Harness Testers_Sampling\" \/>\r\n<\/div>\r\n\r\n\r\nReading is completed.<\/br>\r\nYou can check wires by turning the dial.<\/br>\r\nAfter your confirmation, move on by pressing set button.<\/br>\r\nSelect the data number and name the new data.<\/br>\r\nYou can complete it by selecting \u201cend\u201d.<\/br>\r\n<\/p>\r\n\r\n\r\n\r\n<div class=\"c-spacer--s\">\r\n<img src=\"https:\/\/www.naccorporation.com\/en\/wp-content\/uploads\/2020\/12\/Hi-Pot-Cable-Harness-Testers_-Sampling-Completed.png\" alt=\"Hi-Pot Cable Harness Testers_ Sampling Completed\" \/>\r\n<\/div>\r\n\r\n<hr class=\"c-hr\" \/>\r\n<\/hr>\r\n\r\n\r\n<div class=\"c-spacer--s\">\r\n<h3 class=\"c-headline03\">Test<\/h3>\r\n<p class=\"c-textBig\">\r\nLet\u2019s test with the new data.<\/br>\r\nPlease choose the No.1 Test, on the menu.<\/br>\r\nYou can see the data memorized in the device.<\/br>\r\nStart the test to press the set button.<\/br>\r\nIf the test passes, it shows OK.<\/br>\r\n<\/div>\r\n<div class=\"c-spacer--s\">\r\n<img src=\"https:\/\/www.naccorporation.com\/en\/wp-content\/uploads\/2020\/12\/Hi-Pot-Cable-Harness-Testers_Dielectric-Withstand-Testing.png\" alt=\"Hi-Pot Cable Harness Testers_Dielectric Withstand Testing\" \/>\r\n<\/br>*During Dielectric Withstand Testing\r\n<\/div>\r\n\r\n\r\n\r\n\r\n\r\n<div class=\"c-spacer--s\">\r\n<img src=\"https:\/\/www.naccorporation.com\/en\/wp-content\/uploads\/2020\/12\/Hi-Pot-Cable-Harness-Testers_-Insulation-Resistance-Testing.png\" alt=\"Hi-Pot Cable Harness Testers_Insulation Resistance Testing\" \/>\r\n<\/br>*During Insulation Resistance Testing\r\n<\/div>\r\n\r\n<div class=\"c-spacer--s\">\r\nAfter the test fails, it shows NG.<\/br>\r\nThen you can check the detail by turning the dial.<\/br>\r\n\r\n\r\nIn the NG result, <\/br>\r\nSlash mark \/ means open. hyphen mark - means short.<\/br>\r\n\r\nIn the resistance test NG, the resistance values are displayed.<\/br>\r\nIn the withstand voltage test NG, the leakage current values are displayed.<\/br>\r\nIn the insulation resistance test NG, the resistance values are displayed.<\/br>\r\n<\/div>\r\n\r\n\r\n<div class=\"c-spacer--s\">\r\n<img src=\"https:\/\/www.naccorporation.com\/en\/wp-content\/uploads\/2020\/12\/Hi-Pot-Cable-Harness-Testers_NG.png\" alt=\"Hi-Pot Cable Harness Testers_NG\" \/>\r\n<\/br>*NG in Wiring Testing by OPEN\r\n<\/div>\r\n\r\n<div class=\"c-spacer--s\">\r\n<img src=\"https:\/\/www.naccorporation.com\/en\/wp-content\/uploads\/2020\/12\/Hi-Pot-Cable-Harness-Testers_NG-short.png\" alt=\"Hi-Pot Cable Harness Testers_NG short\" \/>\r\n<\/br>*NG in Wiring Testing by SHORT\r\n<\/div>\r\n\r\n<div class=\"c-spacer--s\">\r\n<img src=\"https:\/\/www.naccorporation.com\/en\/wp-content\/uploads\/2020\/12\/Hi-Pot-Cable-Harness-Testers_NG-in-Resistance-Testing-.png\" alt=\"Hi-Pot Cable Harness Testers_NG in Resistance Testing\" \/>\r\n<\/br>*NG in Resistance Testing\r\n<\/div>\r\n\r\n<div class=\"c-spacer--s\">\r\n<img src=\"https:\/\/www.naccorporation.com\/en\/wp-content\/uploads\/2020\/12\/Hi-Pot-Cable-Harness-Testers_NG-Dielectric-Withstand-Testing.png\" alt=\"Hi-Pot Cable Harness Testers_NG Dielectric Withstand Testing\" \/>\r\n<\/br>*NG in Dielectric Withstand Testing by Leakage Current\r\n<\/div>\r\n<div class=\"c-spacer--s\">\r\n<img src=\"https:\/\/www.naccorporation.com\/en\/wp-content\/uploads\/2020\/12\/Hi-Pot-Cable-Harness-Testers_NG-Insulation-Resistance-Testing.png\" alt=\"Hi-Pot Cable Harness Testers_NG Insulation Resistance Testing\" \/>\r\n<\/br>*NG in Insulation Resistance Testing by Insulation Value\r\n<\/div>\r\n\r\n<h3 class=\"c-headline03\">Test:Start Mode<\/h3>\r\nWhile the machine showing test start, you can change the start mode by turning the dial clockwise.<\/br>\r\nYou can choose Manual, OK wait, After 1 to 10 seconds start.<\/br>\r\nIn particular, OK wait is useful function to conduct the same test consecutively.<\/br>\r\nAfter the test starts by set button and finished with OK,You can start the test by only connecting the new cable.<\/br>\r\nThis function helps you test data quickly.<\/br>\r\n\r\n<div class=\"c-spacer--s\">\r\n<img src=\"https:\/\/www.naccorporation.com\/en\/wp-content\/uploads\/2020\/12\/Hi-Pot-Cable-Harness-Testers_Auto-Start.png\" alt=\"Hi-Pot Cable Harness Testers_Auto Start\" \/>\r\n<\/div>\r\n\r\n<div class=\"c-spacer--s\">\r\n<h3 class=\"c-headline03\">Test:Spec Change<\/h3>\r\n\r\nAfter creating test data, you may need to modify the data.<\/br>\r\nThen please select the data from \u201dtest\u201d.<\/br>\r\nPlease turn the dial counterclockwise while the tester showing the test start.<\/br>\r\nYou can open Spec change mode.<\/br>\r\nPlease set the spec again.<\/br>\r\nYou can finish the settings after you select all specs with the set button.<\/br>\r\n\r\n<\/div>\r\n\r\n<div class=\"c-spacer--s\">\r\n<img src=\"https:\/\/www.naccorporation.com\/en\/wp-content\/uploads\/2020\/12\/Hi-Pot-Cable-Harness-Testers_Spec-Change.png\" alt=\"Hi-Pot Cable Harness Testers_Spec Change\" \/>\r\n<\/div>\r\n\r\n\r\n\r\n\r\n\r\n\r\n<\/div>\r\n\r\n<h3 class=\"c-headline03\">Test:Moment Disconnection Testing<\/h3>\r\nIf you conduct the Moment Disconnection Testing,<\/br>\r\nYou need to add the impacts by hitting or pulling.<\/br>\r\n\r\nAs an example, let's test in the mode monitoring the disconnection until the set button is pressed.<\/br>\r\nAfter applying the specified impact, press the set button.<\/br>\r\n\r\nIf no disconnection occurs, OK is displayed.<\/br>\r\nIf a disconnection is detected, NG is displayed.<\/br>\r\n\r\n<\/p><\/br>\r\n\r\n<div class=\"c-spacer--s\">\r\n<img src=\"https:\/\/www.naccorporation.com\/en\/wp-content\/uploads\/2020\/12\/Hi-Pot-Cable-Harness-Testers_Momentary-Disconnection-Testing.png\" alt=\"Hi-Pot Cable Harness Testers_Momentary Disconnection Testing\" \/>\r\n<\/div>\r\n\r\n\r\n\r\n<div class=\"c-spacer--s\">\r\n<\/div>\r\n<hr class=\"c-hr\" \/>\r\n<\/hr>\r\n\r\n<div class=\"c-spacer--s\">\r\n<h3 class=\"c-headline03\">Search<\/h3>\r\n<p class=\"c-textBig\"><\/p>\r\nSearch is the function to check or test the connection by touching with the probe.<\/br>\r\n\r\nSCAN is for just checking the pin you touch with the probe.<\/br>\r\nTEST is for the test with search test data.<\/br>\r\n\r\nLet's check SCAN.<\/br>\r\nThere are two modes, HOLD and UNHOLD.<\/br>\r\nYou can choose whether or not to keep the last pin touched on the display.<\/br>\r\nIt's useful for checking the continuity of jigs and so on.<\/br>\r\n\r\n\r\n<div class=\"c-spacer--s\">\r\n<img src=\"https:\/\/www.naccorporation.com\/en\/wp-content\/uploads\/2020\/12\/Hi-Pot-Cable-Harness-Testers_Search-Testing.png\" alt=\"Hi-Pot Cable Harness Testers_Search Testing\" \/>\r\n<\/div>\r\n\r\nLet's create search test data.<\/br>\r\nPlease click register. (REG.)<\/br>\r\n\r\n\r\nTouch the pins for reading the wiring.<\/br>\r\nCheck the pins and click register to save data.<\/br>\r\n\r\n\r\n\r\nThe name should be percent or ampersand for the first letter.<\/br>\r\nPercent \"%\" is set for order search.\r\nYou must touch the registered pins in the order to progress the test.<\/br>\r\n\r\nAmpersand \"&\" is set for random search.\r\nYou can touch the registered pins at random order and progress the test.<\/br>\r\n\r\n\r\nLet's open the test data.<\/br>\r\nStart the test.<\/br>\r\nWhen you touch all pins registered, the test is passed.<\/br>\r\nYou can't find the pins, please press ESC button to stop the Test.<\/br>\r\n\r\n<\/br>\r\n<\/div>\r\n<img src=\"https:\/\/www.naccorporation.com\/en\/wp-content\/uploads\/2020\/12\/Hi-Pot-Cable-Harness-Testers_-Search-Testing-OK.png\" alt=\"Hi-Pot Cable Harness Testers_ Search Testing OK\" \/>\r\n\r\n\r\n<hr class=\"c-hr\" \/>\r\n<\/hr>\r\n<div class=\"c-spacer--s\">\r\n<h3 class=\"c-headline03\">Function<\/h3>\r\n<p class=\"c-textBig\">Let's check the function.<\/br>\r\nYou can set Start mode at Function 2.<\/br>\r\n\r\nYou can set Printer setting at  Function 3.<\/br>\r\nYou can set the OK-sound and NG-sound at Function 4<\/br>\r\nIt makes it easier to distinguish when two or more inspectors are working next to each other.<\/br>\r\nYou can select the language at Function 5<\/br>\r\nYou can set the date at function 6<\/br>\r\n\r\n\r\nYou can select the terminal display mode at function 7.<\/br>\r\nYou can set the output for the impactor at function 8.<\/br>\r\nPlease contact us about PLC operation.This is available by customization.<\/p><\/br>\r\n\r\n<img src=\"https:\/\/www.naccorporation.com\/en\/wp-content\/uploads\/2020\/12\/Hi-Pot-Cable-Harness-Testers_Function.png\" alt=\"Hi-Pot Cable Harness Testers_Function\" \/>\r\n\r\n<\/div>\r\n<hr class=\"c-hr\" \/>\r\n<\/hr>\r\n\r\n<div class=\"c-spacer--s\">\r\n<h3 class=\"c-headline03\">Self-Check<\/h3>\r\n<p class=\"c-textBig\">Self check is the function to check the tester itself.<\/br>\r\nPlease conduct test for the daily check.<\/br>\r\nRemove the all test cables from the tester connectors before click TEST.<\/br>\r\n\r\nIt shows \"pass\".The tester is normal.<\/br>\r\nIf NG occurs, please check your environments.<\/br>\r\nPlease contact us in case of tester failure.<\/p><\/br>\r\n\r\n<img src=\"https:\/\/www.naccorporation.com\/en\/wp-content\/uploads\/2020\/12\/Hi-Pot-Cable-Harness-Testers_Self-Test.png\" alt=\"Hi-Pot Cable Harness Testers_Self-Test\" \/>\r\n\r\n<\/div>\r\n<hr class=\"c-hr\" \/>\r\n<\/hr>\r\n\r\n\r\n\r\n<div class=\"u-taCenter\"><a class=\"c-btn c-btn--l p-pageBtnForm\" href=\"\/en\/faq\">Watch More Videos<\/a><\/div>\r\n\r\n","protected":false},"author":1,"featured_media":3235,"menu_order":63,"template":"","meta":[],"video-cat":[150],"video-tag":[140,136],"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/www.naccorporation.com\/en\/wp-json\/wp\/v2\/video-contents\/3234"}],"collection":[{"href":"https:\/\/www.naccorporation.com\/en\/wp-json\/wp\/v2\/video-contents"}],"about":[{"href":"https:\/\/www.naccorporation.com\/en\/wp-json\/wp\/v2\/types\/video-contents"}],"author":[{"embeddable":true,"href":"https:\/\/www.naccorporation.com\/en\/wp-json\/wp\/v2\/users\/1"}],"version-history":[{"count":0,"href":"https:\/\/www.naccorporation.com\/en\/wp-json\/wp\/v2\/video-contents\/3234\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.naccorporation.com\/en\/wp-json\/wp\/v2\/media\/3235"}],"wp:attachment":[{"href":"https:\/\/www.naccorporation.com\/en\/wp-json\/wp\/v2\/media?parent=3234"}],"wp:term":[{"taxonomy":"video-cat","embeddable":true,"href":"https:\/\/www.naccorporation.com\/en\/wp-json\/wp\/v2\/video-cat?post=3234"},{"taxonomy":"video-tag","embeddable":true,"href":"https:\/\/www.naccorporation.com\/en\/wp-json\/wp\/v2\/video-tag?post=3234"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}