{"id":3143,"date":"2022-07-29T05:11:45","date_gmt":"2022-07-28T20:11:45","guid":{"rendered":""},"modified":"2022-09-28T14:40:15","modified_gmt":"2022-09-28T05:40:15","slug":"%e3%80%90%e6%a5%ad%e7%a8%ae%e5%88%a510%e3%80%91%e8%a8%ad%e5%82%99%e6%a9%9f%e5%99%a8%e6%a5%ad%e7%95%8c%e5%90%91%e3%81%91%e3%83%af%e3%82%a4%e3%83%a4%e3%83%bc%e3%83%8f%e3%83%bc%e3%83%8d%e3%82%b9%e3%81%ae","status":"publish","type":"electrical-knowledge","link":"https:\/\/www.naccorporation.com\/en\/learning-center\/electrical-knowledge\/3143","title":{"rendered":"[Industry 10] Testing cables and wire harnesses for the facility equipment industry"},"content":{"rendered":"\r\n<div class=\"c-movie\">\r\n<iframe loading=\"lazy\" width=\"560\" height=\"315\" src=\"https:\/\/www.youtube.com\/embed\/6vSTA8FPJMI\" title=\"YouTube video player\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture\" allowfullscreen><\/iframe>\r\n<\/div>\r\n<div class=\"c-spacer--s\"><\/div>\r\n<h3>Testing cables and wire harnesses for the facility equipment industry<\/h3>\r\n<div class=\"c-spacer--s\">\r\n<h4>1. Overview<\/h4>\r\n<p>\r\nMachines that make things and equipment that help save labor.\r\nThey are evolving day by day to realize new technologies.\r\nHigh-quality wire harnesses are essential for high-precision equipment.\r\nExamples of equipment: Power distribution boards\/control panels\/robots\/elevators\/semiconductor manufacturing equipment, etc.\r\n<\/p>\r\n<div class=\"c-spacer--s\">\r\n<h4>2. Features and testing of control panel\/distribution panel wiring harnesses<\/h4>\r\n<ul>\r\n<li>\u30fbControl panels and switchboards are often manufactured by wiring one circuit in the panel at a time.<\/li>\r\n<li>\u30fbIf the terminal is a connector, inspection is easy. However, if the terminals include round terminals, some effort is required to check for continuity.\r\n<\/li>\r\n<li>\u30fbWiring, resistance, and withstand voltage testing are conducted.<\/li>\r\n<li>\u30fbThe number of test points requires about 1,000 points.<\/li>\r\n<li>\u30fbProducts that support wiring work by confirming continuity with a finger touch are also popular.<\/li>\r\n<\/ul>\r\n<\/div>\r\n<h4>3. Features and testing of wiring harnesses for robots<\/h4>\r\n<ul>\r\n<li>\u30fbNeed for harnesses that can withstand complex movements and bend.<\/li>\r\n<li>\u30fbTwisted pair cables are used to improve noise immunity and communication distance.\r\nsplit pair will cause signal quality degradation, not to mention the lack of expected effect.<\/li>\r\n<li>\u30fbIn addition to wiring and resistance testing, split pair detection can also be performed by the harness tester to ensure high-quality cables.<\/li>\r\n<\/ul>\r\n<div class=\"c-spacer--s\">\r\n<h4>4.Features and testing of wiring harnesses for elevators<\/h4>\r\n<ul>\r\n<li>\u30fbElevator harnesses are long, multi-pointed, and complex.<\/li>\r\n<li>\u30fbWiring and resistance testing are conducted<\/li>\r\n<li>\u30fbProgressive type testing is also effective in improving efficiency. Harness testing equipment can be used for manufacturing instructions and housing.<\/li>\r\n<li>\u30fbIf it is a long cable, the continuity judgment must be delayed and judged correctly.<\/li>\r\n<\/div>\r\n<h4>5. Features and testing of wiring harnesses for semiconductor manufacturing equipment<\/h4>\r\n<ul>\r\n<li>\u30fbHuge harnesses are used in semiconductor manufacturing equipment. Thousands of test points are needed to inspect them.<\/li>\r\n<li>\u30fbAll five electrical testing (wiring, resistance, withstand voltage, insulation, and momentary disconnection) of harnesses are performed.<\/li>\r\n<li>\u30fbHigh-voltage multi-point testers (over 1024 points) are available on custom-order.<\/li>\r\n<div class=\"c-spacer--s\">\r\n<p>Please contact NAC Corporation for quality and efficient testing.<\/p>\r\n<\/div>\r\n<\/div>","protected":false},"author":1,"featured_media":3144,"menu_order":15,"template":"","meta":[],"electrical-knowledge-cat":[127],"electrical-knowledge-tag":[],"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/www.naccorporation.com\/en\/wp-json\/wp\/v2\/electrical-knowledge\/3143"}],"collection":[{"href":"https:\/\/www.naccorporation.com\/en\/wp-json\/wp\/v2\/electrical-knowledge"}],"about":[{"href":"https:\/\/www.naccorporation.com\/en\/wp-json\/wp\/v2\/types\/electrical-knowledge"}],"author":[{"embeddable":true,"href":"https:\/\/www.naccorporation.com\/en\/wp-json\/wp\/v2\/users\/1"}],"version-history":[{"count":0,"href":"https:\/\/www.naccorporation.com\/en\/wp-json\/wp\/v2\/electrical-knowledge\/3143\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.naccorporation.com\/en\/wp-json\/wp\/v2\/media\/3144"}],"wp:attachment":[{"href":"https:\/\/www.naccorporation.com\/en\/wp-json\/wp\/v2\/media?parent=3143"}],"wp:term":[{"taxonomy":"electrical-knowledge-cat","embeddable":true,"href":"https:\/\/www.naccorporation.com\/en\/wp-json\/wp\/v2\/electrical-knowledge-cat?post=3143"},{"taxonomy":"electrical-knowledge-tag","embeddable":true,"href":"https:\/\/www.naccorporation.com\/en\/wp-json\/wp\/v2\/electrical-knowledge-tag?post=3143"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}