{"id":3121,"date":"2021-06-03T04:20:46","date_gmt":"2021-06-02T19:20:46","guid":{"rendered":"https:\/\/www.naccorporation.com\/en\/learning-center\/electrical-knowledge\/%e3%80%90jaso-jis-iec%e3%80%91%e7%9e%ac%e9%96%93%e6%96%ad%e7%b7%9a%e3%81%ae%e8%a6%8f%e6%a0%bc%e3%81%a8%e6%a4%9c%e6%9f%bb%e8%a8%ad%e5%ae%9a%e3%81%ab%e3%81%a4%e3%81%84%e3%81%a6"},"modified":"2022-09-27T10:39:07","modified_gmt":"2022-09-27T01:39:07","slug":"%e3%80%90jaso-jis-iec%e3%80%91%e7%9e%ac%e9%96%93%e6%96%ad%e7%b7%9a%e3%81%ae%e8%a6%8f%e6%a0%bc%e3%81%a8%e6%a4%9c%e6%9f%bb%e8%a8%ad%e5%ae%9a%e3%81%ab%e3%81%a4%e3%81%84%e3%81%a6","status":"publish","type":"electrical-knowledge","link":"https:\/\/www.naccorporation.com\/en\/learning-center\/electrical-knowledge\/3121","title":{"rendered":"[JASO\/JIS\/IEC] Standards and Inspection Settings for Momentary Disconnection Testing"},"content":{"rendered":"<p><img src=\"\/wp-content\/uploads\/2021\/06\/jasojisiec_Momentary-Disconnection.jpg\" alt=\"\u3010JASO\/JIS\/IEC\u3011\u77ac\u9593\u65ad\u7dda\u306e\u898f\u683c\u3068\u691c\u67fb\u8a2d\u5b9a\u5024\u306b\u3064\u3044\u3066\" class=\"alignnone size-full wp-image-2145\" \/><\/p>\r\n\r\n\r\n<p class=\"c-textBig\">Momentary disconnection testing is in increasing demand these days.\r\nIn order to conduct strict testing in accordance with each standard, it is necessary to match the specifications of the Momentary disconnection tester.\r\nNMS10 Momentary disconnection tester is designed for JASO. Testing according to JIS\/IEC standards can be achieved by customization.<\/p>\r\n<div class=\"c-spacer--s\">\r\n<\/div>\r\n<h3>Momentary disconnection testing in automotive standard JASO D616 5.13<\/h3>\r\n<p>In many cases, the JASO standard for momentary disconnection testing in the automotive industry defines a resistance fluctuation of 7 \u03a9 as a momentary disconnection.<\/br>\r\nExample of test settings<\/br>\r\nIn the NMS10 momentary disconnection tester, set the judgment resistance value to 7 \u03a9.<\/br>\r\nThe NM11B momentary disconnection tester can be customized for testing with the momentary disconnection resistance value set to 7 \u03a9.<\/p>\r\n<div class=\"c-spacer--s\">\r\n<h3>Momentary disconnection testing according to JIS C 5402-2-5:2005 (IEC 60512-2-5:2003)<\/h3>\r\n <p>JIS\/IEC standard states that when voltage exceeds 50 % of the supply voltage.<\/br>\r\n(Or when the voltage at both ends of an open contact falls below 50% of the supply voltage).<\/br>\r\n\r\nExample of test settings<\/br>\r\nNMS10 is equivalent to JIS\/IEC standards according to any of the following settings.\u3002<\/br>\r\n\u30fbTesting current 1000mA, momentary disconnection threshold 12\u03a9<\/br>\r\n\u30fbTesting current 100mA, momentary disconnection judgment value 120\u03a9<\/br>\r\n\u30fbTesting current 10mA, momentary disconnection judgment value 1.2K\u03a9\r\n<\/br>\r\n\uff0aThe standard testing voltage of NMS10 is 12VDC. 10VDC or lower can be customized.\u3002<\/p>\r\n<\/div>\r\n<div class=\"c-spacer--s\">\r\n\r\n<\/div>\r\n<a class=\"c-btn c-btn--s u-mr10\" href=\"en\/learning-center\/video-contents\/3232\">Video of momentary disconnection testing (NMS10) <\/a>\r\n<a class=\"c-btn c-btn--s u-mr10\" href=\"en\/products\/178\">Momentary disconnection testing tester NMS10 Product page <\/a>\r\n<a class=\"c-btn c-btn--s u-mr10\" href=\"en\/products\/186\">Momentary disconnection testing tester NM11B Product page<\/a>\r\n<\/br>\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n\r\n","protected":false},"author":1,"featured_media":3122,"menu_order":25,"template":"","meta":[],"electrical-knowledge-cat":[127],"electrical-knowledge-tag":[],"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/www.naccorporation.com\/en\/wp-json\/wp\/v2\/electrical-knowledge\/3121"}],"collection":[{"href":"https:\/\/www.naccorporation.com\/en\/wp-json\/wp\/v2\/electrical-knowledge"}],"about":[{"href":"https:\/\/www.naccorporation.com\/en\/wp-json\/wp\/v2\/types\/electrical-knowledge"}],"author":[{"embeddable":true,"href":"https:\/\/www.naccorporation.com\/en\/wp-json\/wp\/v2\/users\/1"}],"version-history":[{"count":0,"href":"https:\/\/www.naccorporation.com\/en\/wp-json\/wp\/v2\/electrical-knowledge\/3121\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.naccorporation.com\/en\/wp-json\/wp\/v2\/media\/3122"}],"wp:attachment":[{"href":"https:\/\/www.naccorporation.com\/en\/wp-json\/wp\/v2\/media?parent=3121"}],"wp:term":[{"taxonomy":"electrical-knowledge-cat","embeddable":true,"href":"https:\/\/www.naccorporation.com\/en\/wp-json\/wp\/v2\/electrical-knowledge-cat?post=3121"},{"taxonomy":"electrical-knowledge-tag","embeddable":true,"href":"https:\/\/www.naccorporation.com\/en\/wp-json\/wp\/v2\/electrical-knowledge-tag?post=3121"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}